ANT-M01-004

R1-A Training Rig — Component Quick Reference

VacTech Module 1: Orientation & System Familiarisation
System Components
R1-CH
Chamber
TypeCylindrical vessel
FunctionContains the vacuum volume
R1-P-RP
Roughing Pump
TypeRotary vane pump
FunctionCreates vacuum by displacing gas
R1-V-ISO
Isolation Valve
TypeManual valve
FunctionIsolates chamber from pump
R1-V-VENT
Vent Valve
TypeManual valve
FunctionAdmits atmospheric air to chamber
R1-G-CH
Chamber Gauge
TypePirani gauge
FunctionMeasures chamber pressure
R1-G-BX
Barometric Reference
TypeBarometric sensor
FunctionShows local atmospheric (~950 mbar)
Component naming convention: R1 = Rig 1, P = Pump, V = Valve, G = Gauge, CH = Chamber, RP = Rotary Pump, ISO = Isolation, VENT = Vent, BX = Barometric. This naming follows the VacTech component ID standard.
System States
VENTED
R1-V-ISO OPEN
R1-V-VENT OPEN
R1-P-RP OFF
Chamber at atmospheric pressure. Safe to open.
ROUGHING
R1-V-ISO OPEN
R1-V-VENT CLOSED
R1-P-RP ON
Pump is evacuating the chamber. Pressure falling.
ISOLATED
R1-V-ISO CLOSED
R1-V-VENT CLOSED
R1-P-RP OFF
Chamber sealed. Pressure holds if leak-tight.